Filter Results By:

Products

Applications

Manufacturers

Showing results: 181 - 195 of 209 items found.

  • Signal Conditioners

    General Purpose - Encore Electronics, Inc.

    Encore offers a complete line of General Purpose Signal Conditioning instrumentation to meet even the most demanding requirements. Packaged as interchangeable two-channel plug-in modules, Encore’s broad product line includes frequency to voltage converters, strain gage amplifiers, accelerometer conditioners, digital voltmeters and DC power supplies. All of our systems feature a common CAL input on the rear of the rack which allows for calibration of the entire rack. Calibration function varies based on the modules installed. For example, the Model 633 applies a shunt calibration resistor across the bridge, while the Model 149 applies a reference charge source to the input. Contact Encore today and let our team of design engineers help you determine which of our products is best for your application.

  • Trace-Level UV Fluorescence SO2 Analyzer

    Model T100U - Teledyne Advanced Pollution Instrumentation

    The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.

  • PXI Millivolt Thermocouple Simulator Module - 8 Channel

    41-760-004 - Pickering Interfaces Ltd.

    This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 26 or 8 channels—each channel providing a low-voltage output across two connector pins capable of providing ±20mV with 0.7µV resolution, ±50mV with 1.7µV resolution and ±100mV with 3.3µV resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor. For improved accuracy each channel of the Low-Voltage Source carries accurate calibration data stored  on the module. The module also includes a calibration multiplexer for module test and verification purposes.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

  • Timing And Sync

    Safran - Navigation & Timing

    Precision timing is critical for defense and commercial industries and powering essential network operations. Safran offers secure time servers and solutions for accurate network synchronization, ensuring security, compliance, and adherence to best practices. Safran excels in delivering precision timing solutions, including NTPNTP, or Network Time Protocol, is a widely used networking protocol that enables computers and devices to synchronize their system clocks with a reference time source. It ensures accurate timekeeping in computer networks by allowing devices to obtain precise time information from NTP servers, which are typically synchronized to highly accurate atomic clocks. NTP is essential for various applications and services that rely on synchronized time, such as network security, authentication, and data logging. time server appliances and GPSGlobal Positioning System is a navigation satellite system. See also master clocks globally.

  • Adjustable High Frequency Reference Ballast

    HCS-109A - Lisun Electronics Inc.

    HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)

  • Complete Field Meter Site Testing Solution

    7 Series - Powermetrix Systems

    We raised the industry standard by introducing the PowerMaster 7 Series as a true 3-phase analyzing reference standard with internal 3-phase current and voltage source capability. The innovative design of the PowerMaster® 7 Series allows utilities to fully test a metering installation with one piece of equipment. Customer load meter testing, phantom load meter testing, CT burden and ratio testing, CT de-magnetization, PT ratio testing, and transducer testing can all be performed with one solution. In addition, vector diagrams, voltage and current waveforms, and harmonics data up to the 100th harmonic can all be analyzed to complete a true wiring verification.

  • Industrial Calibrators

    Fluke Calibration

    A temperature calibrator, often called a thermometer calibrator, is used to correct inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes. Although simulators are sometimes called temperature calibrators or thermometer calibrators and may be used to provide thermometer calibration for the electronics in an installed system, a temperature source with a calibrated reference sensor is still required to provide a complete and meaningful calibration. Fluke Calibration industrial and field temperature calibrators include: Metrology Wells; Field Metrology Wells; field dry-well calibrators; handheld dry block calibrators; Micro-Baths; large target infrared calibrators; field IR calibrators; ice-point dry-well; and thermocouple furnaces.

  • GPS NTP Time Server - SYNTIME

    Signals & Systems India Private Limited

    Your product description goes hGPS NTP Time Server (SYNTIME) for Network Time Synchronization is a highly accurate time server. It generates time protocols to synchronize NTP/SNTP clients (Simple Network Time Protocol)/PTP clients (Precision time protocol IEEE 1588) over the network and operates at a speed of 10/100/1000Mbps. The NTP server accepts the time and frequency signals from sources like GPS or GLONASS. It achieves nanosecond accuracy and the system clock operates at stratum 1 when synchronized with time sources. It is a sleek, rack-mountable unit that synchronizes and maintains equipment/device time and avoiding any time drifts due to local RTCs. NTP output from time server supports unicast, broadcast, and multicast methods based on selection and behaves like a reference clock for the network. Apart from time synchronization protocols, it supports MD5 (Security key), SNMP, SSH, HTTP (Configuration), TELNET, FTP, and SYSLOG. IP address of the LAN ports can be field configurable.

  • Dual Channel Multi-Band FM Tracking/Data Receiver In Modular Style Housing

    LS-27-B - Lumistar Inc.

    The Lumistar LS-27-B Modular Dual Channel Tri-Band Tracking and Data Receiver is Lumistar’s third generation of modular high performance FM Receivers. This wideband designs supports one or two independent channels of PCM with data rates up to 20Mbps. The unit includes both an optional FM demodulated output for PCM data, and standard programmable AM/linear AGC outputs for auto-tracking receivers. The design offers 8 IF Bandwidths and 8 Video Filters per channel for each receiver.AC coupling with a low pass filter is employed to ensure a high quality data link with long strings of NRZ-L ones or zeroes. The unit provides a software selectable 10 MHz reference I/O port forlocking local oscillators to a high precision external source or to arrange multiple units in a master/slave arrangement. The receiver’s control and status is achieved via Ethernet, USB or auto-switched RS-232 (or “4-wire” RS-485 in place of 232). When utilizing the RS-422 interface, multi-drop configurations can be accommodated.

  • Ettus USRP X410, 1 MHz to 7.2 GHz, 400 MHz Bandwidth, GPS-Disciplined OCXO, USRP Software Defined Radio Device

    787272-01 - NI

    The Ettus USRP X410 integrates hardware and software to help you prototype high-performance wireless systems and perform over-the-air signal generation and analysis. Additionally, the Ettus USRP X410 features a two-stage superheterodyne architecture with four independent transmitter and receiver channels. It also features a Xilinx Zynq Ultrascale+ RFSoC with programmable FPGA supporting the Open Source UHD tool flow as well as LabVIEW FPGA. With these features, the Ettus USRP X410 has the RF and processing performance for applications such as wireless communications prototyping, spectrum monitoring, and signals intelligence. The Ettus USRP X410 is equipped with a GPS-disciplined 10 MHz oven-controlled crystal oscillator (OCXO) Reference Clock, which improves frequency accuracy and synchronization.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Production Line Acoustic Test Chamber

    PLATC - Listen Inc

    The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room

  • Quad RF Driver

    Spectronix

    The Quad RF Driver contains four independent RF channels, each with an RF synthesizer, variable attenuator, and 1W power amplifier.  The RF signal can originate from either the internal synthesizer or an external source via SMA input.  All channels have independent frequency, phase, and gain settings and can be operated in one of two modes.  The “Wideband” mode operates from 35MHz to 2GHz with a 3.472KHz resolution; over this range the frequency roll-off is approximately 0.5dB/100MHz.  “Int-N Phase Adjust” mode allows the user to set and maintain a fixed  phase relationship between all four channels.  This mode is designed to operate between 300 and 460MHz with a 2MHz resolution.  Two additional inputs are provided for an external frequency reference and digital modulation.

  • 1.533 Μm Frequency-Locked Laser

    Thorlabs, Inc.

    Thorlabs' LLD1530 Frequency-Locked Laser is a narrow linewidth, DFB-laser-diode-based, turnkey system with a vacuum emission wavelength of 1532.8323 nm and a high SMSR of at least 35 dB. The laser frequency is actively stabilized to a National Institute of Standards and Technology (NIST)-traceable molecular transition of acetylene and has an absolute accuracy at start-up that is better than ±25 MHz. The emission frequency immediately after start-up is then maintained with a ±25 MHz stability, providing an overall frequency accuracy of ±50 MHz. The LLD1530 is an accurate frequency reference designed to provide low-noise laser emission with excellent frequency stability, accuracy, and precision immediately at start-up. This source is ideal for use in demanding FTIR instrumentation, instrument calibration, gas sensing, and coherent telecommunications applications.

Get Help